Technical Specifications
| Parameter | Value |
|---|---|
| Type | Fully Automatic |
| Brand | Zockethub |
| Notes | One FF596T repeater transmitter PCB allows the connection of up to eight monitored MFP Repeaters (st |
| Weight | 5.0kg. |
| Controls | External (key operated) Reset/Test Scroll; Silence Alarm/Fault Sounders; Evacuate; Disable. Interna |
| IP Rating | IP30. |
| Indicators | Mains On; Gen Fire; Zone Fire; Zone Fault (S/C,O/C,head out,Zone disabled); Sndr Fault; Processor |
| Mains supply | 230V 50/60Hz. |
| Compatibility | Designed to comply with the requirements of BS5839-4 (with head-out monitoring as standard). |
| Auxiliary inputs | Class change input available via optional FF574X expansion loom. |
| Auxiliary relays | 1 x onboard relay (1A,30 VDC,follows sounders). |
| Quiescent Current | 60mA (with no mains supply,fault beeper muted,no aux. output connections,EOL devices and resistor |
| System Components | Fire Alarm Control Panel |
| Eol Resistor Value | 6800 ohm 5 percent Tol. 0/25W (blue,grey,red,gold). |
| Product dimensions | 405 W * 267 H * D 92mm. |
| Construction finish | Metal lid and base. |
| Mains rated current | 330mA max. |
| Internal power supply | 27V nominal. |
| Open collector outputs | 2 x Fire and 1 x Fault output available via optional FF574X expansion loom. Max. sink current 100mA. |
| Call Point Resistor Value | 470 to 680 ohm. |
| Max battery size and type | 2 x 12V 3.2Ah VRLA connected in series. |
| Maximum sounder output current | 1.4mA (to all outputs). Outputs are fused at 1A. |
| Total output current limited to | 1.4A,230V. |
| Number of detector zone circuits | 8 (Max. length per circuit is 500m). Can be extended to 12 zones using an FF501Z 4 Zone extender PCB |
| Maximum devices per detector zone | 20 detectors (max. detector current 2mA). No limit for manual call points. |
| Number of conventional sounder circuits | 4 (Max. length per circuit is 500m). |
Product Description
Conventional smoke detectors are uses cutting-edge art optical chamber combined with an application specific integrated circuit asic to provide fast and precise detection of fires
Shipping Information
Availability
In Stock
Price
Excluding all taxes
Ships from
Coimbatore
Delivery Location
All India delivery available
Shipping
As per delivery location
Seller Information
K
KSK Safety Products
Verified
Coimbatore, Tamil Nadu, India
Established:
2008
Delivery Time:
1–3 Business Days
Shipping Options:
Trust & Safety
Trade Assurance Protected
Secure Payment Methods
Logistics Tracking Available
24/7 Customer Support