Input Power 12kVA Dry Battery Testing Machine, Constant Current Setting Range 01500mA, Isolation Voltage 1000V CH-TO-CH 2000V CH 2000V CH2000V CH-TO-GND

Brand: Quantel
Active
Premium

Key Highlights

Quantel
Request Price
MOQ
1

Available Variants

WhatsApp

Technical Specifications

Parameter Value
Brand Quantel
Model 87001
Altitude 2000 m
Channels 16
Power Out Max. 560W
Protection OQP
Input Power 1.2kVA
Input Current Max. 10A
Input Voltage 1000V CH-TO-CH 2000V CH-TO-GND
Isolation Voltage 1000V CH-TO-CH 2000V CH 2000V CH2000V CH-TO-GND
Operable Environment 0 Degree C ~40 Degree C 0~90% RH (non condensing)
Load Regulation Current Less than 0.01% + 250 Micro A
Load Regulation Voltage Less than 0.01% + 2 mV
Constant Voltage Accuracy 0.02% of F.S.
Current Rise And Fall Times 100us (condition 0A to 5A @200cm Wire)
Constant Current Reading Range 0~520mA
Constant Current Setting Range 0.1~500mA
Constant Voltage Reading Range 0~5200mV
Constant Voltage Setting Range 0 ~ 5000 mV
Transient Overvoltage Mains Supply 2500V
Constant Current Reading Resolution 0.01mA
Constant Current Setting Resolution 0.1mA
Constant Voltage Reading Resolution 0.1mV
Constant Voltage Setting Resolution 0.5mV
No Load Down Programming Voltage Speed 1m sec.

Product Description

Customizable Dry Battery Testing Solutions with OEM Options in Chennai

A 3000 channel data acquisition system das has been designed for testing the progression of life stages of dry batteries. This unique project was done for eveready india ltd. This project was conducted within a view to study the potential for the dry zinc chloride batteries under simulated conditions of their actual pattern in different applications. This particular das has a 32-bit architecture micro, Controller with a baud rate of 19200. The data s are sent to a pc based controller via control area network can bus. The can bus has an advantage of transmitting datas over a longer distance approx. 2 km . The can bus is a two wire system, Thus eliminating the cumbersome usage of a larger number of cables. Here, Not only the life cycle tests are carried but also the initial constituents of the batteries are entered in conjunction with their manufacturing dates. The batch details of the batteries are also entered into the data base. The initial open circuit electrical voltage and short circuit current are noted and fed into the system. After entering these values, The life cycle tests are started. The evaluations consist of founded on, Various types the requirements. Here the batteries are tested over a varied period ranging from a few days to a couple of years. The data s are recorded in a discharge card and stored for future reference. Technical specificationtesting of 192 batteries in just one station 24v dc supply to the entire station micro controller based add, On unit for single modules data transmission through controller area network can bus baud rate of 19200 with 20 samples per second data might be represented as transmitted over a selection of 2 km

Shipping Information

Availability
In Stock
Price
Excluding all taxes
Ships from
Chennai
Delivery Location
All India delivery available
Shipping
As per delivery location

Seller Information

R
Chennai, Tamil Nadu, India
4.7
Rating
98%
Response Rate
Established: 1999
Delivery Time: 4–7 Business Days
Shipping Options:
Air, Sea, Road
View Company Profile

Trust & Safety

Trade Assurance Protected
Secure Payment Methods
Logistics Tracking Available
24/7 Customer Support