Technical Specifications
| Parameter | Value |
|---|---|
| Phase | 3 Phase |
| Weight | 10 |
| USB port | Yes |
| Wireless | Yes |
| Display Size | 12.1 Inch |
| Suitable For | Pediatric, Adult, Neonatal |
| AMC extension | Yes |
| Ethernet port | Yes |
| Input Voltage | 220-240 V |
| Type of alarm | Audio |
| Is It Portable | yes |
| Hard Disk Drive | yes |
| Type of display | LCD |
| Pulse Rate Range | 30-250 bpm |
| Country of Origin | Made in India |
| Respiration Range | tes |
| Cuff leakage alarm | Yes |
| NIBP Cuff Supplied | Adult |
| No of Leads in ECG | 12 |
| Power(Watt) Supply | yes |
| Type of SPO2 probe | Reusable |
| Parameters Measured | NIBP, ETCO2, IBP, RESP, EMG, ECG, PR, Temperature, SPO2 |
| Suspension of Alarm | Yes |
| Water tank Capacity | yes |
| Arrhythmia detection | Yes |
| Cuff disconnect alarm | Yes |
| Maximum Load Capacity | yes |
| Minimum Order Quantity | 10 |
| NIBP Measurement range | 10-270 mmHg |
| SPO2 Measurement Range | 0-50% |
| Temperature probe type | Reusable |
| Type of Battery backup | Lithium Ion |
| Adjustable Alarm Volume | Yes |
| Wall mount availability | Yes |
| SPO2 - low and high alarm | Yes |
| NIBP Measurement Technique | Step Deflation Oscillometric |
| Supplied Temperature Probe | Skin |
| Mean BP - low and high alarm | Yes |
| 12 Lead interpretation of ECG | Yes |
| Low battery voltage indication | Yes |
| Display waveform of Respiration | Yes |
| Heart rate - low and high alarm | Yes |
| Temperature -low and high alarm | Yes |
| Inbuilt thermal Recorder/Printer | Yes |
| Systolic BP - low and high alarm | Yes |
| Diastolic BP - low and high alarm | Yes |
| Respiratory rate - low and high alarm | Yes |
| Sensor/ wire/probe disconnection alarm | Yes |
| Central Patient Monitoring Station Connectivity | Yes |
| Number of leads analyzed for ECG in single time | 3 |
Product Description
Buy Patient Monitor BMK12 with Advanced Multi-Parameter ECG Analysis
Additional specifications include an ECG differential input impedance of 10M, A common mode rejection ratio (CMRR) of 90 dB, And a diagnostic measurement of 105 dB, With typical measurement times for monitoring and operation technique Utilizing a dual-wavelength this device, Optical approach can measure from 0% to 100% with an accuracy as high as 2% for SpO2 levels ranging from 70% to 100%. It also provides PR measurements between 30 and 250 bpm with reliable precision This device operates at a baseline of 2bpm or 2%, Depending on which value is larger, Exhibiting low perfusion performance as low as 0. 3% through CO2 technology and infrared optical methods, With the option for sidestream or mainstream sampling within a defined measuring range With a measurement span of 0 to 150 mmHg, This device offers an accuracy of 2 mmHg for 0-40 mmHg, 5% of the reading for 41-70 mmHg, 8% for 71-100 mmHg, And 10% for 101-150 mmHg, Featuring CSM and EEG for cerebral monitoring sensitivity rating of 400 v with a noise level of 140 dB input With an impedance exceeding 50 mOhm, This device features updates from 0 to 100; a 6. 42 Hz filter applied for 1 second, And a logarithmic EMG percentage filter of 75. 85 Hz, Updated every second This strain gauge transducer operates at 2. 42 Hz with a 1-second refresh interval, Providing an input sensitivity of 5 V/V/mmHg and a measurement range of 50 to 300 mmHg, Ensuring an accuracy of either 2% or 4 mmHg, Based on which is greater Sets the calibration zero for art, Rap, Pa, Lap, Cvp, Icp, Auxp1, And auxp2, Measuring cardiac output and blood temperature within a variety of 23 to 43°C, With precise accuracy With a temperature measuring span of 0 to 20°C and an accuracy of ±0. 5°C, The 0. 5 cinjecta also tracks flow rates from 0. 2 to 20 L/min, Ensuring a measuring accuracy of 0. 2 L/min or 10%, Derived from the higher value Advanced configuration available with ECG, Respiratory monitoring, SpO2, Pulse rate, NIBP, Plus options, And temperature for IBP, EtCO2, Nellcor SpO2, Suntech NIBP, 12-and cerebral cardiac output, Lead ECG, State monitoring through a centralized display interactive display station
Shipping Information
Availability
In Stock
Price
Excluding all taxes
Ships from
New Delhi
Delivery Location
All India delivery available
Shipping
As per delivery location
Seller Information
M
Medical Systems & Services
Verified
New Delhi, , India
Established:
1987
Delivery Time:
30–45 Business Days
Shipping Options:
Trust & Safety
Trade Assurance Protected
Secure Payment Methods
Logistics Tracking Available
24/7 Customer Support