Clamping Voltage Wide DC clamping voltage range 2V-2V, 1V-3V, 1V-12V Other range options available on request, Current Rating AC fault current rating 12 kA, 37 kA and 5kA for 30 cycles Polarization Cells, Brand MCM

Brand: MCM
Active
Premium

Key Highlights

MCM
Request Price
MOQ
1

Available Variants

WhatsApp

Technical Specifications

Parameter Value
Exe Exe (Hazardous Areas 1 and 2)
Brand MCM
DC Spark Lightning DC spark over voltage -600 V
AC Impedance 60 Hz AC impedance of 0.04 ohm
State Current AC steady state current 45 A @ 50/60 Hz
Current Rating AC fault current rating 1.2 kA,3.7 kA and 5kA for 30 cycles
Clamping Voltage Wide DC clamping voltage range +2V/-2V,+1V/-3V,+1V/-12V. Other range options available on request

Product Description

Our team operates as a focused entity that involved in the importation of polarization cells that can control the flow of potentially dangerous ac and dc current in buried surface protected oil & gas, Water pipelines on the buried metallic structures. These grounding cells are installed with high precaution of gas ventilation as improper installation could results in hazardous gases causing explosion and harm. Furthermore these polarization cell also protects against induced ac current and ground fault current on buried pipelines. Preventing from hazardous voltages, These cells permit low, Level voltage of cathodic protection to uniform flow. Precision engineered available at the supplier's location end, These cell consist of multiple steel plates arranged, Fixed and immersed in 30% koh potassium hydroxide solution. Due to this category selected oil, Of construction layer stop the evaporation of solution. These cells are fitted in transparent body for checking solution level. The normal storage of cell serve as a grounding switch in presence of high voltage as they don t have any internal voltage. Working of these cells is derived from the principle of electrochemistry, In which installed plates with large surface area polarize and allow safe dc voltage suitable for cathodic protection to develop. With the increase in voltage, The polarisation film breaks and current is conducted.

Shipping Information

Availability
In Stock
Price
Excluding all taxes
Ships from
Vadodara
Delivery Location
All India delivery available
Shipping
As per delivery location

Seller Information

M
Vadodara, Gujarat, India
4.7
Rating
98%
Response Rate
Established: 1987
Delivery Time: Ready Stock (Immediate Dispatch)
Shipping Options:
Air, Sea, Road
View Company Profile

Trust & Safety

Trade Assurance Protected
Secure Payment Methods
Logistics Tracking Available
24/7 Customer Support