Patient Monitoring System, Measurement Site Upper Arm, Suitable For Neonatal, NIBP Measurement range 10-270mmHg
Active
Premium
Key Highlights
Request Price
MOQ
1
Available Variants
Technical Specifications
| Parameter | Value |
|---|---|
| Analysis | Arrhythmia analysis |
| Parameters | ECG |
| Lead Format | 3 lead |
| Display Type | Digital |
| Measurements | Heart Rate monitoring |
| Suitable For | Neonatal |
| Lead Selections | 1 |
| Heart Rate Range | 15-300 bpm |
| Measurement Site | Upper Arm |
| Pulse Rate Range | 20-200bpm |
| Parameters Measured | ECG, RESP, NIBP, SPO2, Temperature, EEG |
| Blood Pressure Range | 10 to 210 mmHg |
| Pulse Oximetry Range | 0-50% |
| NIBP Measurement range | 10-270mmHg |
Product Description
Advanced Patient Monitoring System for Neonatal and Clinical Use
Further information shows the ECG differential input impedance at 10M, A CMRR of 90 dB for diagnostics, And monitoring operations with a typical measurement time of 105 dB technique Employing a dual-wavelength this instrument, Optical method covers a measurement spectrum from 0% to 100%, Ensuring an accuracy margin of no more than 2% for SpO2 readings between 70% and 100%. Furthermore, It accurately measures PR in the variety of 30 to 250 bpm Featuring a threshold of 2bpm or 2%, Whichever exceeds this product, The other achieves low perfusion performance down to 0. 3% via CO2 technology and infrared with sampling, Optical techniques available in either sidestream or mainstream modes, All within a specified measuring range The device measures from 0 to 150 mmHg, Achieving an accuracy of 2 mmHg within the 0-40 mmHg range, 5% for input sensitivity at 400 v and a noise level reaching 140 dB The system boasts an impedance of over 50 mOhm and a 0-100 update capability; it includes a 1-second filter at 6. 42 Hz, While the EMG percentage updates from 0 to 100 with a logarithmic filter set at 75. 85 Hz Featuring an update rate of 1 second and operating at 2. 42 Hz, This strain gauge transducer offers an input sensitivity of 5 V/V/mmHg, A measuring range of 50 to 300 mmHg, And an accuracy of 2% or 4 mmHg, Depending on which value Configures the zero calibration for art, Rap, Pa, Lap, Cvp, Icp, Auxp1, And auxp2, Facilitating cardiac output measurements and blood temperature readings between 23°C and 43°C, With high accuracy Featuring a temperature range of 0 to 20°C and an accuracy of ±0. 5°C, The 0. 5 cinjecta measures flow from 0. 2 to 20 L/min, With precision set at either 0. 2 L/min or 10% Enhanced configuration that includes ECG, Respiration, SpO2, Pulse rate, NIBP, In addition, And temperature to choices such as IBP, EtCO2, Suntech NIBP, Comprehensive 12, Nellcor SpO2cardiac output, And cerebral, -lead ECG state monitoring touch-enabled terminal
Shipping Information
Availability
In Stock
Price
Excluding all taxes
Ships from
New Delhi
Delivery Location
All India delivery available
Shipping
As per delivery location
Seller Information
M
Medical Systems & Services
Verified
New Delhi, , India
Established:
1987
Delivery Time:
30–45 Business Days
Shipping Options:
Trust & Safety
Trade Assurance Protected
Secure Payment Methods
Logistics Tracking Available
24/7 Customer Support