Portable patient monitor with a user, Friendly touch, Screen now with masimo set pulse oximetry!ecg, Respiration, Masimo spo2, Noninvasive arterial pressure and temperature. Offered alongside a printer. Featuring cutting, Edge innovations and impeccable craftsmanship, The dre waveline ez patient monitor is the perfect choice for healthcare professionals who demand precision, Performance and affordability. It features an intuitive touchscreen that supports your needs quickly and accurately evaluate resulting in, Patient conditions better patient care. Utilize the waveline ez to monitor ecg, Respiration, Spo2, Nibp you will, And temperature find also available with etco2 monitoring and a printer. Features touch, Screen provides immediate operationsimultaneous multi, Lead ecg monitoringnew for 2015! masimo set pulse oximetry ask your dre representative for detailsadvanced st and arrhythmia detectiongraphical and tabular trendingdisplays three waveformsbattery backupaudible and visual alarmsquick bp readings recallecg patient safety standard iec60601, 1, 1988cmrr 60db common mode rejection ratio heart rate range 20 ~ 254bpm 1bpmheart rate averaging 8 second averagest segment range, 0. 8 ~, 0. 8mvinterface aami 6, Pinlead selection i, Ii, Iii 3 lead mode i, Ii, Iii, Avr, Avl avf, V 5 lead mode st and arrhythmia analysis lead fault alarm audible, Visual input 5, Lead ecg patient cableqrs indicator audible and visual alertwaveform storage 6 minutessweep speed 12. 5/25/50 mm/secgain selection 4mv, 2mv, 1mv, 0. 5mv, 0. 25mv, Autotrends 2 hours, > 4 hours, > 8 hours, > 24 hours, > 48 hourspatient isolation breakdown voltage 4000vac 50hz 60 seconds leakage current frequency width monitoring mode 0. 5 ~ 40hz, 0. 4db,,3. 0db surgery mode 0. 5 ~ 20hz, 0. 4db,, 3. 0db not calibration significantpatient drive current enclosure leakage current maximum t wave rejection capability 1. 2mvheart rate alarm response time < 7 secondsaspect ratio 0. 24 ~ 0. 6 sec/mvalarm frequency low alarm 2, 2. 4khz high alarm 3, 3. 4khzdefibrillator protected & esis protected tested with 5kvrecovery time following defibrillation resp measurement method thoracic impedancerespiration rate range 0 ~ 1001rpmaccuracy 2 rpmnibp method automatic oscillometricparameters systolic, Diastolic, Mean pulsescale mmhg, Arterial pressure or kpaoperating modes manual, Automatic, Continuousrepeat cycles 1 ~ 10, 15, 30, 60, 90, 120 minutesdetermination systolic, Adult/pediatric 40 ~ 250mmhg 5. 3 ~ 33. 3kpa systolic, Neonate 20 ~ 160mmhg 2. 7 ~ 21. 3kpa diastolic, Adult/pediatric 10 ~ 180mmhg 1. 3 ~ 24. 0kpa diastolic, Neonate 10 ~ 140mmhg 1. 3 ~ 18. 7kpa cuff pressure range adult/pediatric 0 ~ 300mmhg 0 ~ 40. 0kpa neonate 0 ~ 140mmhg 0 ~ 18. 7kpa initial cuff inflation adult/pediatric 17010mmhg 22. 7 1. 3kpa neonate 10010mmhg 16. 0 1. 3kpa deflation pressure 30mmhg 4. 0kpa exceeding the last systolic pressurecuff inflation rate no greater than 50mmhg/secmeasurement typical stat 20 secondspressure, Time typical 25 seconds, Maximum 40 seconds display accuracy 3mmhgbp pulse rate accuracy 2% @ 40 ~240bpmcuff neonate, Infant, Pediatric, Standard adult